Kent and Canterbury HospitalProject Outline:To refurbish an existing CT suite and associated control room within a live hospital imaging department, preparing the area for replacement imaging equipment and associated services.
-
Royal Victoria Infirmary, NewcastleProject Outline:To refurbish an existing angiography laboratory and control room, preparing the clinical environment for new specialist imaging equipment while working within the requirements applicable to a Higher-Risk Building.
-
King's College Hospital - First FloorProject Outline:To alter and adapt an existing hospital area to create two new angiography examination rooms together with the associated clinical, patient and technical accommodation. -
Stoke CDCProject Outline:To deliver the specialist environments required for a new multi-modality diagnostic imaging facility, incorporating X-ray, CT and MRI accommodation within a larger construction project. -
Andover War Memorial HospitalProject Outline:To carry out a complete refurbishment of an existing X-ray room within a live department, including changes to improve bed access and accommodate a revised equipment layout.
-
Royal Hampshire County Hospital - Second FloorProject Outline:To replace two existing mammography rooms within the department while minimising the overall period of disruption to the hospital's mammography service.
-
Princess Elizabeth Hospital, GuernseyProject Outline:To replace the existing fluoroscopy system within Fluoroscopy Room 3, while improving the layout of the space and creating a better working and patient environment. The new installation changed the orientation of the equipment and relocated electrical plant outside the main examination room.
-
St Thomas' Hospital - First FloorProject Outline:To replace an existing MRI system that had been out of service for almost 12 months, restoring an important imaging facility for patients and clinical teams as quickly and safely as possible.
-
Andover War Memorial HospitalProject Outline:To deliver a new, single-storey MRI imaging suite at Andover War Memorial Hospital, providing the local community and surrounding areas with improved access to MRI services and reducing the need for patients to travel to alternative facilities. -
Hammersmith HospitalProject Outline:Replacement of existing obsolete PET CT with a pet CT of the latest technology for detailed high level reserch. -
Basildon General HospitalProject Outline:Replacement of 4 existing obsolete Catheter Labs. -
Southampton General HospitalProject Outline:Installation of 2 magnetic resonance imaging (MRI) systems designed by Siemens Healthcare Systems for imaging of Neurological patients. -
LiverpoolProject Outline:A multi-modality equipment project which was originally undertaken by a previous main contractor, and which was then taken over for completion by another contractor. -
BirminghamProject Outline:Upgrade of the existing Siemens MRI scanner to a newer platform. -
HartlepoolProject Outline:Replacement of the current Siemens Healthineers MRI scanner.
Case Study
Addenbrooke’s Hospital – Pathology Laboratories
Location: Addenbrooke's Hospital – Fourth & Fifth Floors, Pathology Wing
Value of Works: £890,000
Time on Site: 14 Months - Phased Programme
Purpose of the Project
To refurbish areas across the fourth and fifth floors of the hospital’s Pathology Wing to enable the installation of new pathology equipment while allowing the wider department to remain operational.
Works Undertaken on Site
The project was delivered across six separate phases over a 14-month programme.
Temporary fire-rated partitions were installed to isolate each work area from the live department. ABC then delivered the required mechanical and electrical services and finishes within each phase.
Individual areas were completed and formally handed over before staff occupied them and the programme progressed to the next phase.
Full handover and witnessing of the installed systems was undertaken on completion.
Challenges
Maintaining operational pathology services throughout the programme was the principal challenge.
Careful phasing was essential to ensure construction activities, equipment installation and the continuing use of adjacent areas could operate safely alongside one another.
ABC’s Site Manager and Project Manager worked closely with the hospital estates team, equipment supplier and users to coordinate programme dates for each phase.
The M&E design was similarly developed around the hospital’s existing systems, with user meetings helping to ensure the completed installations met operational requirements.
More Projects